Everpure MRS-350BL EV9970-20 Reverse Osmosis System
Everpure MRS-350BL EV9970-20 Reverse Osmosis System
The Everpure MRS-350BL EV9970-20 Reverse Osmosis System features an adjustable blend valve.
Product Description
Everpure MRS-350BL EV9970-20 Reverse Osmosis System includes:
The BL Series features an adjustable blend valve, which allows custom tailoring of the dissolved mineral content in the treated water. With this feature, a controlled amount of raw water is mixed with the Reverse Osmosis water to create a blend containing the desired level of TDS (Total Dissolved Solids). After blending, the water passes through a sub-micron carbon filter. This final filtration step removes tastes and odors, and insures delivery of ingredient quality water.
Part Number: EV9970-20
“CC” models introduce a small amount of hardness minerals back into the treated water
Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up
Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages
Wall mount design allows flexible installation
Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs
Scale reduction reduces energy costs
This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results
Specifications:
Overall Dimensions: 30” H (34” H – CC Model) x 15” W (20.5” Wwith Prefilter) x 8“ D 762 mm H (864mm H – CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D
Voltages:
115VAC/60Hz (NEMA 5-15P Plug)
230VAC/50Hz (“Schuko” CEE 7/7 Plug)
240VAC/50Hz (AS 3112 Plug)
Inlet and outlet connection: 3/8″ OD tube connection
Wastewater line connection: 1/4″ OD tube connection
Service Flow Rate: Dependant on water pressure in storage tankand line size(s) to equipment
Pressure Requirements:
Operating: 25 – 80 psi (172-552 kPa), non-shock
Maximum Static: 100 psi (689 kPa), non-shock
Water Supply: 0.7 gpm (2.7 lpm)
Inlet Temperature: 40°F – 100°F (4-38°C)
Inlet TDS: 1,500 ppm max recommended
Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks)
Operation Tips
Change filter cartridges on a regular 6-month preventative maintenance program
Change RO cartridges on a regular 2-year preventative maintenance program
Change cartridges when capacity is reached
Always flush the filter cartridge at time of installation and cartridge change
Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
Raw water hardness in excess of 7 grains per gallon should be softened
The raw water may contain particulates and the use of a pre-filter is recommended
Contact EVERPURE Technical Service for pre-treatment recommendations
Installation Tips
Choose a mounting location suitable to support the full weight of the system when operating
Deliming of equipment prior to application is recommended
Never use saddle valve for connection
Use 3/8” (10 mm) water line
The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
Allow clearance to right of unit for optional prefilter
Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up